preamp gain | sensor sen. (V/m/s) | sensor damping | sensor freq. (Hz) | sampling rate (Hz) | instrument response | |
Quanterra Q330 + Nanometrics T240 | 1 | 1200 | 0.707 | 240s~223Hz | 100 | |
Texan_1 (#WO開頭) |
32 | 29.4 | 0.5 | 4.5 | 250 | 'zeros': [0j, 0j] 'poles': [(-14.137+24.486j), (-14.137-24.486j)] ‘sensitivity’: 29.4 * 32 * 5.243e+05 (垂直軸極性相反) |
Texan_2 (#WO3及#開頭) |
32 | 82 | 0.707 | 4.5 | 250 | 'zeros': [0j, 0j] 'poles': [(-19.99+20.00j), (-19.99-20.00j)] ‘sensitivity’: 82 * 32 * 5.243e+05 (垂直軸極性相反) |
Zland | 36 dB (63.09) |
76.7 | 0.707 | 5.0 | 500 | 'zeros': [0j, 0j] 'poles': [(-21.991+22.435j), (-21.991-22.435j)] ‘sensitivity’: 76.7 * 1000 (垂直軸極性相反,水平軸極性正常) |
SmartSolo | 30 dB (31.62) |
76.7 | 0.707 | 5.0 | 250 | 'zeros': [0j, 0j] 'poles': [(-21.991+22.435j), (-21.991-22.435j)] ‘sensitivity’: 76.7 * 31.62 * 1000 (三軸極性相反) |
CUBE (3C geophone) |
16 | 16 | 0.707 | 4.5 | 200 | 'zeros': [0j, 0j] 'poles': [(-19.781+20.202j), (-19.781-20.202j)] 'sensitivity': 4096000 * 27.7 (極性正常) |
Instrument | 優 | 缺 | Note |
Zland | 電池、3分量geophone、紀錄器一體,安裝方便,可同時充電與資料下載 | 無法傳輸即時資料。中心站需要220V電源,原始資料為單一檔案其容量較大(數10GB),轉檔需要額外軟體,目前無法野外延長電池容量 | |
SmartSolo | 電池、3分量geophone、紀錄器一體,安裝方便,中心站110V/220V電源可用,軟體可直接輸出daily MSEED,特殊型號可搭配外部電池來延長運作時間 | 無法傳輸即時資料。 | 價格較低。主體可分離,充電與資料下載獨立進行,維修角度以及無接點外露是優點,但需要多一步驟來分離是缺點。 |
Texan | 使用兩顆1號電池運作,亦可外部電源運作,中心站資料下載作業方便 | 單分量紀錄器,無法即時傳送資料,電力不足時資料會遺失 | |